| 弾性係数 | 20.0 °C | 74.0 GPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 伸び | -196.0 °C | 0.6 % | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| -196.0 °C | 2.4 % | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| -120.0 °C | 0.5 % | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| -120.0 °C | 2.4 % | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| -50.0 °C | 1.0 % | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| -50.0 °C | 2.4 % | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 0.8 % | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 1.0 % | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 1.0 – 4.0 % | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 2.2 % | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 2.2 – 2.4 % | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 2.4 % | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 220.0 °C | 10.6 % | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 220.0 °C | 28.4 % | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 280.0 °C | 30.1 % | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| ブリネル硬度 | 20.0 °C | 75.0 | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 80.0 | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 80.0 – 110.0 | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 85.0 – 115.0 | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| ポアソン比 | — | 0.33 | — | — | 鋳造 3xx.x 系アルミニウムの典型値 |
| せん断弾性係数 | — | 2.8 GPa | — | — | 鋳造 3xx.x 系アルミニウムの典型値 |
| せん断強さ | 20.0 °C | 201.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 引張強さ | -196.0 °C | 277.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| -196.0 °C | 304.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| -120.0 °C | 256.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| -120.0 °C | 275.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| -50.0 °C | 246.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| -50.0 °C | 263.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 200.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 220.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 220.0 – 320.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 235.0 – 251.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 235.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 240.0 – 320.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 241.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 241.0 – 304.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 251.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 20.0 °C | 304.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 220.0 °C | 68.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 220.0 °C | 75.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |
| 280.0 °C | 48.0 MPa | T5 | DIN 1725-2, EN 1676, EN 1706 | |